Guides

Is air conditioning bad for the environment? Refrigerants, R32 and carbon in Leeds

A modern split air conditioner used only for cooling in a Leeds home carries more climate risk in its refrigerant than in its electricity. A typical 2.5kW R32 unit holds 0.95kg of gas worth 0.64 tonnes of CO2 equivalent if it all escaped, while a year of cooling on the UK grid produces about 13kg. This guide sets out the numbers behind that: the global warming potential of R32, R410A and R290, the UK F-Gas phase-down, when the grid is cleanest, how a portable compares, and why a unit used for heating can cut a household's carbon instead of adding to it.

15 min read · Last updated:

Is air conditioning bad for the environment?

A modern 2.5kW split air conditioner used for cooling produces about 13kg of CO2 equivalent a year from UK electricity, so its running carbon is small. That figure comes from the 92 kWh a year on the EU energy label of a Daikin wall unit, multiplied by the government's carbon factor for electricity. The bigger risk sits inside the pipes: 0.95kg of R32 refrigerant, equal to 641kg of CO2 if the whole charge leaked.

The honest answer has two parts. The electricity side in Britain is modest and getting cleaner. The refrigerant side depends on the installer: joints that hold, a proper pressure test, and gas recovered at the end of the unit's life.

There is a third part. Many split systems, including the Daikin model used here, are reversible heat pumps, and a unit that replaces gas heating in one room saves several hundred kilograms of CO2 a year.

Where the environmental harm actually comes from

An air conditioner affects the climate in two ways. The electricity it uses comes partly from gas-fired power stations, and the refrigerant inside it is itself a greenhouse gas.

For electricity, the government's 2026 greenhouse gas conversion factors give 0.13096kg of CO2 equivalent per kWh generated in the UK, plus 0.01299kg for losses in transmission and distribution. Added together, each kWh used at home carries about 0.144kg. Natural gas burned in a boiler is 0.18231kg per kWh. Those two numbers decide almost every comparison in this guide.

For refrigerant, the measure is global warming potential (GWP): how much heat a kilogram of the gas traps over 100 years compared with a kilogram of CO2. GOV.UK's guide to calculating the CO2 equivalent of an F gas sets the method: mass in tonnes multiplied by GWP. A sealed system that never leaks releases none of it.

How R32, R410A and R290 compare

These are the three refrigerants a Leeds homeowner is most likely to meet. The legal GWP figures are the ones GB law uses for labelling and leak checks, taken from GOV.UK's list of F gases and their GWPs. The reporting figures come from the DESNZ conversion factors, which use a newer scientific assessment.

  • R32 (difluoromethane): legal GWP 675, DESNZ reporting factor 677, no ozone depletion. The standard gas in new UK wall splits and many heat pumps.
  • R410A (a blend of R32 and R125): legal GWP 2,088, DESNZ factor 1,924. Found in many older splits, and banned in new single splits under 3kg since 2025.
  • R290 (propane): DESNZ factor 0.06, which is effectively zero. Used in portable units such as the Meaco covered below. It sits in safety group A3, the highly flammable class, in the European Commission table linked in the next section.
  • R22 (an HCFC): ozone depleting potential 0.055 on GOV.UK's ozone-depleting substances list. No longer allowed in new equipment or for servicing.

Kilogram for kilogram, R410A traps a little over three times as much heat as R32 (2,088 divided by 675 is 3.09).

Why the same gas has two different GWP numbers

You will see R32 listed as 675 on a label, 677 in a carbon report and 2,690 in some campaign material. The 675 figure is written into the F-Gas rules and GB law uses it for labels, leak-check thresholds and quotas. The 677 figure in the DESNZ factors comes from a later IPCC report. The 2,690 figure is a 20 year GWP, shown in the European Commission's table of climate-friendly alternatives for air conditioning. R32 does most of its warming in its first couple of decades, so the 20 year figure is four times the 100 year one. Use the label figure to compare systems, and treat any leak as worse in the short term than 675 suggests.

Worked example: one Leeds living room unit over a year

Take a 1930s semi in Roundhay with a gas boiler, and a Daikin FTXM25A wall unit with an RXM25A outdoor unit fitted in the lounge. Every input comes from Daikin's FTXM-A and RXM-A product flyer and the DESNZ factors above. You can repeat the sums with your own unit's data sheet.

  • Refrigerant: 0.95kg of R32. 0.95 divided by 1,000, multiplied by 675, gives 0.64 tonnes (641kg) of CO2 equivalent, released only if the whole charge escapes.
  • Cooling: the label gives 92 kWh a year at a SEER of 9.47. That figure assumes 350 full-load hours (2.5kW multiplied by 350, divided by 9.47, is 92). 92 kWh multiplied by 0.144 is 13kg of CO2 equivalent a year.
  • Heating: the label gives 647 kWh a year at a SCOP of 5.20 in the EU average climate. That delivers about 3,364 kWh of heat (647 multiplied by 5.20). The electricity is 647 multiplied by 0.144, or 93kg.
  • The same heat from a 90% efficient gas boiler needs 3,364 divided by 0.9, or 3,738 kWh of gas. At 0.18231kg per kWh that is 681kg.

Using the unit to heat that lounge saves about 588kg of CO2 equivalent a year (681 minus 93). Even in the worst case, where the entire refrigerant charge leaked once, the heating saving would cover it in about 13 months.

Laboratory SCOP figures flatter real Leeds winters, when damp near-freezing mornings force defrost cycles. Run the same sums at a SCOP of 3.5 and the electricity rises to 961 kWh, or 138kg, so the saving falls to about 543kg a year. The full-leak payback stretches to around 14 months. The conclusion does not change.

Running costs follow the same pattern. On the October to December 2026 Ofgem price cap of 26.32p per kWh for electricity and 7.97p for gas, the year's cooling costs about £24. Heating the lounge costs about £170 at SCOP 5.20, £253 at SCOP 3.5, and about £298 from the gas boiler. Our air conditioning running costs guide has room-by-room figures.

Cooling only: when the refrigerant outweighs the electricity

Many Leeds households want cooling and nothing else, and keep the gas boiler for heat. For them the balance flips.

Ten years of cooling at the label's 350 hours a year adds up to about 132kg of CO2 equivalent from electricity. The refrigerant charge is worth 641kg. If a cooling-only system leaks its charge once in that decade, the leak is almost five times the carbon of all the electricity it used. If it never leaks and the gas is recovered at the end, the lifetime figure stays close to 132kg.

That is why installation quality is the main environmental lever for a cooling-only buyer. A split system is joined on site, so its joints are made in your house by the engineer. Daikin's installer reference guide for the RXM-A outdoor units calls for a nitrogen pressure test and vacuum drying before the gas is released into the pipework. Our guide to checking an F-Gas registered installer explains how to confirm the person doing that work is certified. Home systems this size sit below the 5 tonne CO2 equivalent threshold (about 7.4kg of R32) in GOV.UK's leak checking guidance, so no leak check is legally required.

Hot summers push usage above the label's assumption. The Met Office Bradford station record, the closest to Leeds in its historic station series, shows an average July maximum of 20.4°C for 1991 to 2020 (our average of the monthly figures). July 2026 averaged 23.1°C.

When is the grid cleanest? What NESO's 2025 data shows

Britain's electricity is far cleaner than it was. The National Energy System Operator's historic generation mix and carbon intensity data records a 2025 average of 127g of CO2 per kWh, against 445g in 2009 and 505g in 2012. Carbon Brief's analysis of 2025, which adjusts the NESO data to cover the whole UK, puts it at 126g.

The average hides a pattern that suits air conditioning. We split NESO's 17,520 half-hourly readings for 2025 by season and time of day:

  • Summer afternoons, 12 noon to 6pm BST in June, July and August: 87g per kWh.
  • Winter evenings, 4pm to 8pm in January, February and December: 172g per kWh.
  • The whole of 2025: 127g per kWh.
  • 2026 so far, to 4 November: 141g per kWh.

Cooling demand peaks on sunny afternoons, when solar output is highest. On those averages, a kilowatt-hour used on a summer afternoon carried about half the carbon of one used on a winter evening. You can check the live picture for Yorkshire on NESO's Carbon Intensity site. Between 7:30 and 8am on 19 November 2026, its forecast for the Yorkshire region was 81g per kWh, with wind supplying 52.5% of the mix.

If you heat with the unit, a timer that warms rooms before 4pm shifts some use out of the dirtiest winter hours.

Portable units: a cleaner gas but more electricity

Portable air conditioners in Britain must use a gas with a GWP of 150 or less, under the GB bans on F gas in new products. In practice that means propane. The MeacoCool MC 9000 portable, for example, holds 260g of R290, worth about 0.016kg of CO2 equivalent on the DESNZ factor. On refrigerant alone the portable wins easily.

The electricity tells a different story. The Meaco draws 1,005 watts for 9,000 BTU (about 2.64kW) of cooling, an efficiency of roughly 2.6. The Daikin split draws 480 watts for 2.5kW, an efficiency of 5.2. Over a summer of 200 hours at full output, the portable uses about 201 kWh (29kg of CO2, about £53 at the price cap) and the split about 96 kWh (14kg, about £25).

A portable is the lower-carbon choice for a few hot days a year in one room. For regular cooling the split uses half the electricity, so it wins on running carbon and cost as long as its refrigerant stays sealed. Add heating and the split wins by a wide margin. Our guide to cheap air conditioning units compares the three-year costs.

What the F-Gas phase-down means for a system you buy now

Great Britain is cutting the supply of HFC refrigerants in steps. GOV.UK's F gas guidance says the UK is phasing down HFCs by 79% by 2030, measured against average use between 2009 and 2012.

Two rules matter most to homeowners. Since 2025, new single split systems holding under 3kg of refrigerant cannot use a gas with a GWP of 750 or more, which ended R410A in new domestic splits and left R32 at 675. Movable units are capped at 150. Defra consulted in late 2025 on a faster phase-down. Its May 2026 update on the HFC phasedown consultation says it will not legislate in 2026 to change the steps that apply from 1 January 2027, and that it remains committed to reform.

The EU has gone further. Under EU Regulation 2024/573, summarised on the same European Commission air conditioning page, new split air-to-air systems up to 12kW that use a gas with a GWP of 150 or more are banned from 1 January 2029, and all F gases in splits of that size from 2035, except where safety rules require otherwise. Those dates do not apply in Great Britain.

None of this makes an R32 system bought today illegal to own or service. The GB bans control what can be placed on the market new. The GB phase-down implements the UK's obligations under the Kigali Amendment, which sets an 80 to 85% cut in HFCs by the late 2040s.

Older R22 and R410A systems in Leeds homes and offices

Some older systems in West Yorkshire shops, offices and homes may still hold R22. GOV.UK's ozone guidance says these gases must not be used to service existing equipment, so a leaking R22 unit cannot legally be topped up. You can keep using one as long as it is not leaking.

R410A systems are more common in homes. They are legal to run and service, but each kilogram is worth 2.09 tonnes of CO2 equivalent, against 0.68 tonnes for R32. When an R410A unit fails out of warranty, an R32 replacement cuts the warming effect of each kilogram of refrigerant by about two-thirds. Compare the old unit's SEER and SCOP with the new one's data sheet to see the electricity saving.

If the old unit is still sound, there is no environmental gain in ripping it out early. Get it serviced and plan the replacement for when it needs a major repair. The servicing page covers what an annual check involves.

Does air conditioning damage the ozone layer?

Not if it was made in the last 20 years or so. R32, R410A and R290 have no ozone depleting potential. The damage came from CFCs and then HCFCs such as R22, which the Montreal Protocol phased out. UNEP describes the 2016 Kigali Amendment as extending the same treaty to HFCs, which were brought in as ozone-safe replacements but warm the climate.

Heating with it: the bigger carbon story in a Leeds winter

In Leeds, heating is where an air-to-air system earns its environmental keep. Leeds City Council declared a climate emergency in March 2019. Its climate change page commits to making the city carbon neutral by 2030 and lists district heating in city centre buildings among its actions. For a stone terrace or 1930s semi heated by a gas boiler, the savings in the worked example apply room by room.

Air-to-air units can qualify for help. GOV.UK's Boiler Upgrade Scheme page offers £2,500 towards an air-to-air heat pump, provided it replaces fossil fuel or electric heating and is fitted by an MCS certified installer. Hybrid systems that keep a gas boiler do not qualify. Installation of heat pumps in homes is zero-rated for VAT until 31 March 2027 under VAT Notice 708/6, reverting to 5% after that. The installers we work with are MCS certified and apply the 0% rate on domestic installs. Our air-to-air heat pump guide covers eligibility and the hot water question in detail.

The Energy Saving Trust's air-to-air heat pump advice suggests trying shading and ventilation first, and using the heat pump for cooling only if the home still overheats.

How to cut the environmental impact of your system

Use this as a checklist when you get quotes and when the system is running.

  • Size the unit to the room. An oversized unit holds more refrigerant than the room needs and cycles on and off more often.
  • Compare SEER for cooling and SCOP for heating. A SEER of 9.47 uses about 31% less electricity than 6.5 for the same cooling (1 divided by 9.47 against 1 divided by 6.5).
  • Keep pipe runs short. On the Daikin RXM-A range, every metre beyond 10m needs another 0.02kg of R32.
  • Ask the installer to confirm a nitrogen pressure test and vacuum before the gas is opened, and to give you the commissioning record.
  • Keep the label showing gas type, mass, CO2 equivalent and GWP. GOV.UK's F gas labelling rules require installers to fit one.
  • Book a service if cooling drops off or the outdoor unit ices up heavily. Both can point to a slow leak.
  • When the unit is replaced, make sure the old refrigerant is recovered and not vented.

What happens to the refrigerant at the end of the unit's life?

It must be taken out by a qualified technician before the unit is scrapped. GOV.UK's guidance on recovering, reclaiming and recycling F gas lists stationary air conditioning, portable units and heat pumps among the equipment where recovery is compulsory. The recovered gas has to go to a licensed waste facility by a registered waste carrier, where it can be reclaimed to the standard of new gas, recycled or destroyed. Venting it on purpose is against the law.

A removed outdoor unit should leave your house either pumped down with its gas still inside or with the gas recovered into a cylinder. Ask whoever takes it away where the gas is going. A proper answer names the recovery and the destination.

Getting a lower-carbon install in Leeds and West Yorkshire

If you are weighing up home air conditioning in Leeds and the environmental side matters to you, put three questions to every installer. Which refrigerant and charge does the proposed unit use? What are its SEER and SCOP? How will the pipework be pressure tested and how will old equipment be dealt with? Clear written answers tell you more about the carbon than any brochure.

For a heat pump that replaces gas in Leeds, Bradford, Wakefield, Harrogate or Huddersfield, ask for a heat loss figure and a BUS-ready quote. For cooling only, ask for the smallest unit that covers the room and a short pipe run. Request a free quote and we will pass your details to an MCS certified partner installer covering your area.

Frequently asked questions

Ready to get air conditioning prices?

Tell us what you need and we'll help connect you with a suitable local air conditioning specialist across Leeds and West Yorkshire.

Get a Free Quote
Get a Free Quote