Air conditioning leaking water, not cooling or smelling: a fault-finding guide

Water dripping from an indoor unit is usually condensate that cannot get away down a blocked, kinked or badly sloped drain hose, and a unit that blows air but will not cool should be checked for a dirty filter, a wrong setting or weather outside the unit's operating range before anyone is called out. This guide sets out the checks a homeowner in Leeds and West Yorkshire can safely do, the error codes and symptoms that mean you should switch off, and the jobs that by law need an F-Gas qualified engineer.

14 min read · Last updated:

Why is my air conditioner leaking water?

An air conditioner leaks water indoors when the condensate it pulls out of the room air cannot drain away, usually because the drain hose is blocked with dust, crushed, or no longer runs downhill. Daikin's FTXM operation manual puts it plainly: if the drain hose is crushed or clogged, water cannot drain and starts leaking, so stop the unit and contact your dealer. Mitsubishi Electric lists the same symptom first in the "when you think that trouble has occurred" section of its MSZ-AP operating instructions.

A wall-mounted split uses no mains water. Every drop comes from your room air: moisture condenses on the cold indoor coil, runs into a tray and leaves through a hose that goes out through the wall with the refrigerant pipes. Block that path and the tray overflows down the front of the unit.

Mitsubishi adds that dust building up inside over several seasons can grow mould and clog the drain passage. Daikin says that above 80% room humidity in COOL or DRY, dew can form on the casing and drip.

How much water should a working split produce?

More than most people expect. The MSZ-AP20VG, a common 2kW Mitsubishi Electric bedroom unit, splits its rated cooling into 1.50kW of sensible cooling (lowering the temperature) and 0.50kW of latent cooling (pulling moisture out), measured with the room at 27°C dry bulb and 19°C wet bulb.

Latent cooling is the energy taken out by turning water vapour back into liquid. Engineering ToolBox's water property tables give 2,477kJ for every kilogram of water condensed at 10°C. The value only moves from 2,491kJ at 4°C to 2,458kJ at 18°C, so the choice of temperature barely changes the answer. You can repeat the sum yourself:

  • 0.50kW is 0.50kJ every second, so 0.50 x 3,600 = 1,800kJ of latent cooling in an hour.
  • 1,800 / 2,477 = 0.73kg of water an hour, and a kilogram of water is a litre.
  • Over a 4 hour summer evening that is 4 x 0.73 = 2.9 litres from one small unit.

That is roughly 12ml a minute from a small unit in muggy weather, so a blocked hose fills the tray quickly and leaks tend to show on the first humid day of the year. On a dry day the unit produces far less, and in heating mode the indoor unit produces none.

Daikin's own test follows from this: if no water comes out of the outside end of the drain pipe while the unit is cooling, the pipe may be clogged and an indoor leak may follow. In a Leeds summer the hose end is usually visible on the wall below the unit.

What an owner can check on a leaking unit

Switch the unit off with the remote first. If water is running near the plug, the isolator or a socket, turn the circuit off at the consumer unit before you touch anything, then go through these in order:

  • Look at the outside end of the drain hose. It should hang freely with its end clear of the ground. Mitsubishi's MSZ-AP installation manual shows at least a 50mm gap between the hose end and any water in a gully, because a submerged end stops the flow.
  • Follow the hose along the wall. The same manual says it must run downward the whole way, with no section raised above the unit and no sagging "waves" where water can sit.
  • Check whether leaves, moss or a wasp nest have blocked the open end. Clearing the outside tip with your fingers is fine. Do not push wire up the hose, as you cannot see the tray end.
  • Look for water dripping from a drain hose inside the room. Where a hose runs through a room or a cupboard it should be wrapped in insulation, and an unwrapped one sweats on humid days.
  • Clean the air filters, which Daikin and Mitsubishi both say to do about every 2 weeks.

If the hose is clear and sloped and the unit still drips, stop and call the dealer, as Daikin and Mitsubishi both advise. Mitsubishi also says the user should never wash the inside of the indoor unit, because unsuitable detergent can damage the plastic and cause leaks, or reach the motor and electrics and cause smoke or fire. That rules out the coil-cleaning sprays sold online.

Leaks that are engineer jobs

A blocked drain tray, a perished internal hose, a cracked tray, a failed condensate pump (fitted where the hose cannot fall by gravity, such as a unit on an internal wall) and a unit hung off level all need the casing off. So does a unit that drips while icing up, because ice on the coil points to low airflow or low refrigerant. Mitsubishi's installation manual draws three hose faults that cause water leakage: a hose raised above the outlet, a hose that waves up and down, and a hose end sitting in water.

On older stone terraces in Leeds and Bradford the hose often runs down a front wall to a gully or straight onto the pavement. If a unit was moved, the wall was repointed, or a new downpipe was fitted, the hose may have been lifted or crushed by accident. That is the first thing to look at after any outside building work. Our terraced house guide covers where condensate is normally routed on back-to-backs and through terraces.

Air conditioning not cooling: what to rule out first

Daikin's own troubleshooting list for a room that will not cool costs nothing to work through. Check the airflow is not on "quiet" or speed 1, the mode is COOL and not DRY, the set temperature is below the room temperature and the louvres point into the room. Furniture below or beside the unit, a dirty filter, an open window or a running extractor fan will all cut the cooling you feel.

Timing catches people out. After a power cut, or a quick off and on, the Daikin FTXM waits about 3 minutes before restarting, and after the breaker goes back on it can take 3 to 10 minutes. Daikin units also drop to a gentle breeze once the room reaches the set temperature.

Daikin's last item matters too: depending on the number of people and the outdoor temperature and humidity, the set temperature may not be reached. A small unit in a south-facing loft room with four people in it may be working correctly and still be too small. Our guide to what size air conditioner you need shows how to check.

Can the Leeds weather stop an air conditioner cooling?

Yes, in spring and autumn more often than in summer. Each model has an outdoor temperature range for cooling, and Daikin says a safety device may stop the unit outside it. Compare two popular models with the 1991 to 2020 averages from the Met Office Bradford station, the closest long-running station to Leeds with published monthly data:

  • Daikin FTXM (operation manual): cooling from 10°C to 46°C outside as standard, room 18°C to 32°C, room humidity 80% at most. A switch on the outdoor PCB extends cooling down to -10°C, which is an engineer setting.
  • Mitsubishi Electric MSZ-AP20VG (operating instructions): cooling guaranteed from -10°C to 46°C outside, with the room between 21°C and 32°C.
  • Bradford average daily maximum: 9.5°C in March, 12.5°C in April, 13.4°C in October and 9.6°C in November, all from the Met Office file. Average minimums sit between 2.9°C and 7.1°C in those months.

So a garden office or conservatory in West Yorkshire can overheat behind glass on a bright March or November day while it is still below 10°C outside. A unit with a 10°C lower limit may stop then, and that is not a fault. Your model's limits are on the specification page of its manual. If you need cooling on cold sunny days, ask an engineer about the low-ambient setting.

What the error code on the display means

Daikin units can show a two-character code through the remote control, which Daikin's FTXM manual lists in full. Write the code down before you reset anything, because a reset can clear it. Here are the codes most often linked to leaking or not cooling, and what each means for you:

  • U0, refrigerant shortage. Engineer only. The system has lost gas, which means there is a leak to find.
  • A5, high pressure control or freeze-up protector. Clean the filters and clear the airflow, then call an engineer if it returns.
  • A6 or E7, fan motor faults. Engineer only.
  • U4, failure of transmission between the indoor and outdoor units. Engineer only, as it usually needs the interconnecting cable or a board checked.
  • E5 or E6, compressor overload or faulty start-up. Engineer only.
  • 00, normal. No fault is stored.

Other brands use different codes, so use the table in your own manual. A blinking operation lamp on a Daikin with no code you can read still means "check the error code and consult your dealer", in Daikin's words.

Ice on the pipes, a hissing sound or no cooling at all

Mitsubishi says that when an air conditioner does not cool or heat, there is a possibility of a refrigerant leak, and if you find one you should stop the unit, ventilate the room well and call your dealer. Do not wait for a smell. Both Daikin and Mitsubishi warn that refrigerants may not contain an odour, and Mitsubishi adds that leaked refrigerant in contact with a flame or a heater element creates harmful gas, so keep fan heaters and gas hobs away from a suspected leak.

Finding and repairing a refrigerant leak is not a DIY job. GOV.UK's guidance on qualifications to work with F gas says working on F gas equipment without the correct qualification is against the law and can bring a civil penalty. Category 1 covers all work, category 2 covers systems holding less than 3kg (most single-room home splits; the MSZ-AP20VG holds 0.55kg of R32) and category 4 covers leak checks that do not break into the circuit. A business doing this work for others also needs company F gas certification, and our F-Gas registered installer check shows how to look one up.

Expect a proper repair to include finding the leak, fixing it, pressure testing and then recharging. A "regas" with no search for the leak simply puts gas back into a system that is still losing it.

Air con smells: musty, damp, burning or something else

Most smells from a split are the room's own smells coming back. Daikin's manual says the indoor unit blows out odours it has absorbed from walls, carpets, furniture and clothes, and that after long use a dirty heat exchanger or fan can give off a smell of its own. Its advice is to have the indoor unit cleaned by your dealer and not to spray the unit with deodorisers. Mitsubishi says dust inside the unit can create an unpleasant odour and help mould grow.

A musty smell in the first minutes after switching on usually means mould or bacteria on the coil, fan or drain tray. Clean the filters first. If it carries on, the fix is an engineer's internal clean, which our air conditioning service cost guide covers. Smell plus water marks on the wall below the unit means a leak as well.

A burning or electrical smell is different. Daikin and Mitsubishi both say: stop the unit and turn off the circuit breaker, then call the dealer. The same applies to a power cable that is hot or damaged, or a breaker that trips again and again. Do not reset a breaker more than once on a unit that smells of burning.

Damp matters for health. The UK Government's guidance on the health risks of damp and mould in the home says damp and mould mainly affect the airways and lungs, causing cough, wheeze and shortness of breath, and that dampness alone can raise the risk even when no mould is visible. A wall soaked by a leaking unit for a summer is worth sorting quickly, especially where someone in the house has asthma.

Water and ice from the outdoor unit in winter

Water from the outdoor unit is normal. In heating mode the outdoor coil runs below freezing, frost builds up, and the unit defrosts itself. Daikin says heating stops for about 4 to 12 minutes while it does this, with a flowing or whistling sound and water or steam coming off the outdoor unit. In cooling mode, moisture condenses on the cold outdoor pipework and drips. None of this needs an engineer.

Where that water goes is the West Yorkshire problem. Bradford averages 8.8 days of air frost in December, 8.8 in January and 8.2 in February, about 26 frosty days across the three months. Mitsubishi's installation manual warns against using the outdoor drain socket in cold regions because it may freeze, and tells installers to site the unit so frozen drain water does not damage the ground. On a terrace where the outdoor unit hangs over a shared path or front step, that can mean ice every frosty morning, so ask an engineer about piping the drain to a gully. Do not chip ice off the coil: Daikin says not to speed up defrosting by any means other than those it recommends.

Owner jobs and engineer jobs side by side

Owners can safely clean or wash the filters, change the remote batteries, check modes and settings, clear leaves from around the outdoor unit with the power off, check the outside hose end and its slope, reset the breaker once after a power cut, and read the error code. Daikin says to switch off the breaker before clearing a blocked inlet.

Everything else is an engineer job: anything with the casing off, the drain tray and pump, the fan, circuit boards and wiring, refrigerant pipework, leak searches and gas, internal coil cleans, and any unit that trips the breaker more than once. Daikin says not to repair or modify the unit yourself because of the risk of shock or fire, and Mitsubishi says the user should not disassemble, alter or repair it. Our aircon repair in Leeds page covers what engineers need from you.

Renting in Leeds: whose problem is a leaking unit?

If your landlord fitted the air conditioning, a leak from it is usually theirs to fix. Shelter's guidance on damp and mould in private rented homes says landlords must fix problems that cause damp, including faulty installations and leaking internal pipes. Leeds City Council's page on help for private tenants asks you to report it to your landlord in writing, allow around 14 days and keep copies, after which its Private Rented Housing team may help where damp is linked to leaks. Council tenants report to the council's damp and mould team, whose damp, mould and condensation page says significant hazards are investigated within 10 working days.

What to tell the engineer when you book

Note the make and model from the label on the side of the indoor unit, its rough age, any error code, whether the problem is in cooling, heating or both, and when it started. Photos of the outside drain hose and outdoor unit help, as does mentioning any recent work on that wall. Check your warranty paperwork first, as terms differ by brand. Regular air conditioning servicing in Leeds keeps drains and coils clean before they leak. When you are ready, request a free quote with the symptoms and code and we will pass it to an independent local engineer.

Frequently asked questions